2.
Press and hold the guide stopper on the inlet pipe
down through the locking hole on the cyclone body
using the hand tool with a point. Then detach the inlet
pipe from the cyclone body.
4
1
Fig.50
► 1 . Inlet pipe 2. Guide stopper 3. Cyclone body
4. Locking hole
3.
Clean off any substance found in the air channels.
Foreign substance is likely to get stuck around an
incoming air port.
1
Fig.51
► 1 . Suction inlet 2. Incoming air port
4.
locked.
3
Fig.52
► 1 . Inlet pipe 2. Cyclone body 3. O-ring 4. Flap valve
2
5.
the cleaner body.
2
18 ENGLISH
Insert the inlet pipe back in place until it is securely
3
4
1
NOTICE:
Be sure that the O-ring and flap valve
are securely in place before reassembly. Suction
performance can be affected if the cyclone unit is
operated without the O-ring and flap valve in place.
Reassemble the cyclone unit, and attach it onto
2