Operating Instructions
Fault
The device does not heat
up.
The appliance heats up
unevenly.
The device does not cool.
The display of the active
operating mode shows
nothing or the device
cannot be operated.
EN
The optional heated lamp
gantry does not work
1
only for installation with additional fixed heated lamp gantry
10.1 Faults and fault messages
Possible cause
The setting button was pressed for too
long.
Connection between control and heating
elements interrupted
The sensor for temperature detection is
defective.
A single heating element is damaged
The setting button was pressed for too
long.
Connection between control and cooling
element interrupted
The sensor for temperature detection is
defective.
The cooling technology is defective
The setting button was pressed for too
long.
Power supply is interrupted
Display defective
Connection between control and heated
1
.
lamp gantry interrupted
Control defective
There is a fault in the heated lamp gantry.
Inform a service technician in the event of a fault.
Hot and cold plate
Remedy
Press and hold the setting button for 5
seconds to switch the associated display
and function back on.
The connection must be checked by a
specialist and restored if necessary.
The sensor must be checked by a
specialist and replaced if necessary
The heating elements must be checked by
a service technician and replaced if
necessary.
Press and hold the setting button for 5
seconds to switch the associated display
and function back on.
The connection must be checked by a
specialist and restored if necessary.
The sensor must be checked by a
specialist and replaced if necessary
The cooling element and the cooling loops
must be checked by a refrigeration
specialist and replaced if necessary.
Press and hold the setting button for 5
seconds to turn the display and function
back on.
The power supply must be checked by a
specialist and restored if necessary.
The display must be checked by a
specialist and replaced if necessary.
The connection must be checked by a
specialist and restored if necessary.
The control unit must be checked by a
specialist and replaced if necessary.
Observe the information in the operating
instructions for the heated lamp gantry.
Page 22