i.
Reassemble the filters group (F1-F2) inserting the rear edge inside the grid (fig.
37).
l.
Manually close the air suction grille (3) (fig. 37).
To deactivate the LED A (if on), after cleaning and repositioning the filters, electrically
connect the appliance then press the reset key H briefly using a pointed object.
In this way, the signal relating to the need for filter cleaning is reset.

4.2 - MAINTENANCE

If you plan to idle the unit for a long time, perform the following:
a. Stop the air conditioner and disconnect the power supply.
b. Remove the batteries from the remote control.
Do not perform them alone.

4.2.1 - Routine maintenance

The air conditioner that you have purchased has been designed to reduce routine
maintenance operations to a minimum.
These operations involve solely the cleaning operations outlined below:
• Cleaning or washing of the ambient air filter every 2 weeks or every time the
relative red LED lights up (this can be done by the user, see user manual).
• Cleaning of the condensing battery and cleaning of the condensate management
system.
These operations must be carried out by skilled technicians on a regular basis that
will depend on the place of installation and intensity of use.
Depending on the quantity of dirt, the unit can be cleaned dry (by using a battery
compressor and bowl and cleaning the fins with a soft brush taking care not to deform
them) or more thoroughly using dedicated detergents.

4.2.2 - Condensation water drainage in case of emergency

If anomalies occur in the condensa-
tion water disposal system, the air
conditioner stops and signals the
alarm status with the intermittent
lighting up of LED A, LED B and
LED C (fig.30).