Prism Converti À 230 Volts; Avertissements - HotSpring LIMELIGHT Serie Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Modèle BEAM II 230 volts, connecté de manière permanente
L'EMPLACEMENT PHYSIQUE EXACT DES BORNES SUR LE DISJONCTEUR DIFFÉRENTIEL
THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER
VARIERA ENTRE LES FABRICANTS. CONNECTER LE FIL CHAUD À LA BORNE NEUTRE
WILL VARY BETWEEN MANUFACTURERS. CONNECTING THE HOT WIRE TO THE
ENDOMMAGERA LE BOÎTIER DE CONTRÔLE DE MANIÈRE IRRÉVERSIBLE.
NEUTRAL TERMINAL WILL CAUSE IRREVERSIBLE DAMAGE TO THE CONTROL BOX.
DISJONCTEUR
230V, 50 Amp,
BIPOLAIRE (NON
2-POLE,
DIFFÉRENTIEL) 230
CIRCUIT BREAKER
V, 50 A
(NON GFCI)
8 AWG BLANC,
NEUTRE
# 8 AWG WHITE, NEUTRAL
10 AWG VERT, TERRE**
# 10 AWG GREEN, GROUND**
8 AWG BLEU, L1
# 8 AWG BLUE, L1
8 AWG ROUGE, L2
# 8 AWG RED, L2
PANNEAU
MAIN SERVICE
ÉLECTRIQUE
ELECTRICAL
DE SERVICE
PANEL
SECTEUR
MOINS DE 100 PIEDS
** Consultez la norme NEC 250-122 (tableau)
** Refer to NEC 250-122 (table)
REMARQUE : les connexions de câble vers les disjoncteurs différentiels sont uniquement indiquées à titre de référence. Veillez toujours à ce que le câble blanc neutre
NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker.
soit connecté à la charge neutre du disjoncteur de 30 ampères.
*PROVIDED WITH HOT TUB.
*FOURNI AVEC LE SPA.
PRISM CONVERTI À 230 VOLTS
Le modèle PRISM nécessite un disjoncteur supplémentaire de 16 A pour faire
fonctionner le réchauffeur et la pompe 3 simultanément. Sans ce disjoncteur
supplémentaire de 20 A, le réchauffeur NE FONCTIONNERA PAS alors que les jets
sont utilisés avec la pompe à jets 3 activée.
Ce tableau électrique secondaire nécessite une alimentation électrique monophasée
de 70 ampères, 230 volts (phase, neutre, terre). Le câble de terre ne doit jamais être
inférieur à 10 AWG. Utilisez la norme NEC 250-122 (tableau) et les codes locaux
pour de plus amples informations. Un câble en cuivre plein de 6 AWG minimum est
également nécessaire.
Montez le tableau électrique secondaire à proximité du spa, mais pas plus près que
DISJONCTEUR BIPOLAIRE
(NON DIFFÉRENTIEL)
230 VCA, 70 A
6 AWG BLANC, NEUTRE
6 AWG VERT, TERRE
6 AWG BLEU, L1
6 AWG ROUGE, L2
PANNEAU
ÉLECTRIQUE
MOINS DE
DE SERVICE
SECTEUR

AVERTISSEMENTS

UTILISEZ UNIQUEMENT DES CONDUCTEURS EN CUIVRE
UTILISEZ DES CÂBLES D'ALIMENTATION ADAPTÉS À 75 °C/167 °F.
DÉCONNECTER TOUTES LES CONNEXIONS D'ALIMENTATION AVANT UN
ENTRETIEN.
CONNECTEZ UNIQUEMENT À UN CIRCUIT PROTÉGÉ PAR UN DISJONCTEUR
DIFFÉRENTIEL DE CLASSE A.
Exigences électriques
English
Spanish
AVERTISSEMENT !
IMPORTANT!
TERRE 10 AWG VERT
GROUND # 10 AWG GREEN
*TABLEAU
*SUBPANEL
ÉLECTRIQUE
WITH GFCI
SECONDAIRE AVEC
BREAKERS
DISJONCTEURS
DIFFÉRENTIELS
IMPORTANT: ALL WIRING SHOULD BE COPPER.
IMPORTANT : TOUS LES CÂBLAGES DOIVENT ÊTRE EN CUIVRE
ILLUSTRATION DE CÂBLAGE
230 VCA, 56 A, 60 Hz, PRISM (CONVERTI)
100
PIEDS
TABLEAU ÉLECTRIQUE
SECONDAIRE AVEC
DISJONCTEURS
.
DIFFÉRENTIELS
Page 28
French
RÉCHAUFFEUR
FACTORY
CÂBLÉ EN
WIRED
USINE
HEATER
L1, 12 AWG BLEU
L1 # 12 AWG BLUE
L2, 12 AWG ROUGE
L2 # 12 AWG RED
N 12 AWG BLANC
N # 12 AWG WHITE
L1, 10 AWG BLEU
L1 # 10 AWG BLUE
L2, 10 AWG ROUGE
L2 # 10 AWG RED
Minimum 5 PIEDS
Minimum 5 FEET
le tableau électrique secondaire
The Subpanel must be
doit être visible depuis le spa
Prise de terre du système
within sight of the spa
System Ground Terminal
Ne pas dépasser 50 PIEDS.
Do not exceed 50 FEET.
BOÎTIER DE CONTRÔLE
cinq pieds, conformément à tous les codes locaux.
LES SPAS HOT SPRING DOIVENT ÊTRE CÂBLÉS EN RESPECTANT
TOUTES LES RÉGLEMENTATIONS ÉLECTRIQUES LOCALES.
TOUTE L'INSTALLATION ÉLECTRIQUE DOIT ÊTRE CONFIÉE À UN
ÉLECTRICIEN AGRÉÉ ET EXPÉRIMENTÉ. NOUS RECOMMANDONS
L'UTILISATION DE CÂBLES, DE RACCORDS ET DE FILS
ÉLECTRIQUES APPROPRIÉS POUR TOUS LES CIRCUITS.
IMPORTANT : un technicien de maintenance doit reconfigurer le spa à
l'aide de cavaliers souples afin de permettre au réchauffeur du spa de
fonctionner en même temps que la pompe à jet.
REMARQUE : des chemins de câbles longs peuvent nécessiter une plus
grande épaisseur de fil que celle indiquée.
L1, PHASE, 12 AWG BLEU
L2, PHASE, 12 AWG ROUGE
L1, PHASE, 12 AWG BLEU
L2, PHASE, 12 AWG ROUGE
L1, PHASE, 10 AWG BLEU
L2, PHASE, 10 AWG ROUGE
N, NEUTRE 10 AWG BLANC
N TERRE, 6 AWG VERT
PLUS DE 5 PIEDS
LE TABLEAU ÉLECTRIQUE
SECONDAIRE DOIT ÊTRE VISIBLE
DEPUIS LE SPA
NE PAS DÉPASSER 50 PIEDS
CES SPAS DOIVENT ÊTRE UTILISÉS AVEC UN TABLEAU ÉLECTRIQUE SECONDAIRE À
DISJONCTEUR DIFFÉRENTIEL FOURNI.
TOUS LES MODÈLES DE SPA CANADIENS UTILISENT UN CÂBLE 8 AWG VERT, TERRE.
UN CÂBLAGE INCORRECT ENDOMMAGERA LES CIRCUITS IMPRIMÉS.
CONSULTEZ LES INSTRUCTIONS DE CÂBLAGE INCLUES AVEC LE SOUS-PANNEAU POUR
DES INSTRUCTIONS DE CÂBLAGE DÉTAILLÉES.
GRD
Enlevez les cavaliers A
de TB-1
B
OÎTIER DE
COMMANDE
Tabla de contenido
loading

Tabla de contenido