* The non-rewirable plug must never be used without a fuse cover
being fitted.
The correct replacement for the detachable fuse cover is identifiable
from the manufacturer's reference number stamped on the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki
Parts/Service Centres.
Fuses should be rated at 10A and approved to BS 1362.
5. WATER SUPPLY AND DRAIN CONNECTIONS
WARNING
Connect to potable water supply only.
* The connections to the mains water supply must be made in
accordance with the countries' current requirements of the Water
Supply or Water Fittings Regulations.
* Icemaking water must be potable water. Where scaling can be
caused by water quality, installation of an external filter or softener
is recommended. Contact your local water treatment professional or
Hoshizaki service agent.
* Water supply pressure should be minimum 0.07 MPa (0.7 bar) and
maximum 0.8 MPa (8 bar). If the pressure exceeds 0.8 MPa (8 bar),
use a pressure reducing valve. Do NOT throttle back the supply tap.
* Be sure to use the new hose-sets supplied with the appliance. Do
not reuse any old hose-sets.
* A plumbing permit and services of a licensed plumber may be
required in some areas.
* Water should drain into an open trap.
* The icemaker drain is gravity flow, so ensure drain pipe has an
adequate pitch or fall.
* To prevent a backflow into the storage bin, the outlet hose must be
laid as shown in Fig. 2.
GOOD
Downgrade
Fig. 2
1) Attach the free end of inlet hose to the stop valve (Fig. 4), noting
washer is correctly positioned. Hand tighten sufficiently to provide
leak free joint. It is a wise precaution to have the stop valve within
easy reach.
2) Hand tighten grey flexible outlet hose (accessory) onto the fitting
on the rear of the icemaker as indicated (Fig. 3), ensuring rubber
sealing washer is correctly positioned to obtain a leak free joint.
The pipe can be cut to length as necessary to suit position of main
drain. To prevent water leaks, secure the outlet hose to the drain
outlet by using a hose band.
Note: Jointing compounds should be approved and suitable for
potable water use.
Power Supply Cord
Outlet Hose
Power Supply Cord
BAD
Upgrade
BAD
II. OPERATING INSTRUCTIONS
1. This icemaker is designed to produce and store edible ice.
To keep the icemaker hygienic:
* Wash your hands before removing ice. Use the plastic
scoop provided (accessory).
* The storage bin is for ice use only. Do not store anything
else in the bin.
* Clean the storage bin before use (see "III. 1. CLEANING").
* Keep the scoop clean. Clean it by using a neutral cleaner
and rinse thoroughly.
* Close the door after removing ice to prevent entrance of
dirt, dust or insects into the storage bin.
3
ENGLISH
Drain Outlet
Inlet Hose
European Model
Fig. 3
Water Supply Tap
Inlet Hose
Fig. 4
WARNING