Technical Specifications; Instructions For The Installer - Royal Catering RC-523M Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

________________________________________________________________ use and instruction manual _

3. Technical specifications

Dimensions of appliance LxDxH (mm)
Weight (Kg)
Maximum load per tray (kg)
Total load trays (kg)
Convection heating element (kW)
Max. absorbed power (kW)
Power supply voltage (V)
Power cable diameter
Type of cable
Connecting electric cable
Class
Degree of protection against humidity
Water pressure
(kPa)
The noise level of the appliance in operation is below 70 dB (A).
The "technical data" plate is positioned on the side panel of the appliance.

4. Instructions for the installer

The following instructions are aimed at the qualified installer, to ensure that he carries
out the installation, adjustment and maintenance operations as correctly as possible and
according to current legal regulations. Any operation must be performed with electrical
power cut to the appliance.
Before using the appliance, carefully remove the special adhesive film protecting the parts
in stainless steel. Do not leave any glue residues on the surfaces. If necessary, remove them
at once, with an appropriate solvent.
Fitting the feet - The feet are inside the appliance and must be secured on the four
threaded holes on the base. If necessary, the height of the feet can be adjusted by screwing
or unscrewing.
Positioning - Position the appliance perfectly horizontally on a table or similar support (the
table or support must be at least 85 cm above the floor). Position it at a distance of not less
than 10 cm from the side and rear walls, to enable natural ventilating air to circulate freely
around it. The appliance is ventilated through specific openings on the metal walls of the
outer housing , and ensures efficiency and long-life. For this reason it is strictly forbidden to
obstruct these ventilation openings, even partially or for short periods. Failure to observe this
specific prohibition releases the manufacturer of the appliance from all responsibility and
immediately voids any guarantee rights for the said appliance, because its constructive
conformity has been voluntarily compromised. Furthermore, the appliance is not suitable for
embedding and for grouped positioning with other identical appliances.
Electrical connection - The appliance must be connected to the electrical mains according
to current legal regulations. Before making the connection, make sure of the following:
-
the voltage and frequency values of the power supply system match the values on
the "technical data" plate affixed on the appliance;
-
the limiting valve and the system are able to support the appliance's load (see the
"technical data" plate);
-
the power supply system has an adequate earth connection according to current
_ page 4 _____________________________________________________________________________________
610x729x660
44
2
10
3
3,2
230V~ (50Hz)
2
3x1,5 mm
H07RN-F
Tipo Y
I
IPX3
100-200
Tabla de contenido
loading

Este manual también es adecuado para:

10011954

Tabla de contenido