Model
Digital 30 V
Digital 50 V
Digital 80 V
Digital 100 V
The outside casing of the EWH is made of impact-resistant plastic. Inner tanks have a
special bio-glass-porcelain coating reliably protecting the inner surface against chemi-
cal corrosion. The space between the outside casing and the inner tank is filled with
polyurethane foam - a modern, ecologically clean thermal insulation, which has the
best heat-saving characteristics. Digital models have two screwed nozzles: for inlet of
cold water (Figure 1, p. 3) with a blue ring and for outlet of hot water (Figure 1, p. 2)
— with a red ring. The control panel, in all models, is on the front side of the EWH.
(Figure 1, p. 16).
Tubular heating element (THE), thermostat and thermal switch sensors are mounted
on the removable flange. THE is used to heat water and thermostat provides with pos-
sibility of heating temperature regulation up to +75°С. All models have electronic
control with sensor adjustment. Electronics maintain automatically water temperature
at the level set by the user. The thermostat is used for protecting against EWH over-
heating, which disconnects THE from power supply when water temperature exceeds
95°С. (Fig. 3).
Safety valve (Fig. 1, p. 5) operates as the check valve, ensuring protection of the water
ingress from the water heater into the sewage system in case of pressure drop in the
sewage system and in case of pressure rise in the tank at high water heating, as well as
the functions of the safety valve, releasing overpressure in the tank at high water heat-
ing. During water heater operation water may leak out of the exhaust outlet pipe of the
safety valve to relieve excessive pressure, which is made for the purpose of water
heater safety. This outlet pipe shall remain open to the atmosphere and be installed
constantly down.
Drainage of water from the safety valve exhaust pipe into the drain shall be pro-
vided with installation of the corresponding EWH drainage.
It is required regularly (at least once a month) to discharge a small amount of water
through the exhaust pipe of the safety valve into the drain to remove lime deposits and
to test the operating functionality of the valve. Handle (Fig. 1, p. 15) is intended to open
the valve. It is necessary to control when operating water heater this handle to be in
position closing water draining from the tank.
2
4.
DESCRIPTION AND PRINCIPLE OF OPERATION
Average heating time
Code
T = 45° C at 2 kW
111 214
111 215
111 216
111 217
Installation
0 h 47 min.
1 h 19 min.
2 h 06 min.
2 h 38 min.
Table 1
vertical
vertical
vertical
vertical