INSTALLATION INSTRUCTIONS
Ensure the valve stem adapter is lightly placed over the spline adapter.
Place the handle assembly over the valve stem adapter.
Turn the handle clockwise until the stop is contacted. The valve will be in the full cold position. The handle
should be between 9 and 10 o'clock positions. To adjust the position of the handle, refer to the alignment
instructions below.
Rotate the handle assembly counterclockwise, through the detent, then to the high temperature limit stop.
Verify that the handle assembly is between the 3 and 4 o'clock position.
Rotate back to the 6 o'clock position.
Remove the handle assembly and set aside.
Handle Alignment Adjustments
NOTE: The spline adapter allows fine adjustment of the handle alignment.
Remove the handle assembly and the valve stem adapter.
Reposition the spline adapter.
Reinstall the handle assembly and the valve stem adapter.
Check the alignment.
Repeat until the handle alignment is satisfactory.
1491208-2-A
4 of 16
2. ADJUST THE HANDLE ASSEMBLY
Thermostatic Valve Trim
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.