Temperature Control; About Your Heat Pump; Quick Heat Recovery - GE Zoneline AZ9VH Manual Del Propietario E Instrucciones De Instalación

Ocultar thumbs Ver también para Zoneline AZ9VH:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Features

Temperature Control

This unit must be controlled by a Class 2 remote control
wall mounted heating and cooling thermostat, minimum
2C/2H. Standard thermostats used on prior models are

About Your Heat Pump

Heat pumps can save money by removing heat from the
outside air—even when the outside temperature is below
freezing—and releasing that heat indoors.
To get the best energy performance from your heat
pump, don't change the room thermostat by more than
one degree at one time. Raising the heat setting 2–3
degrees may cause the Zoneline to use its electric heating
elements in order to reach the new temperature setting
quickly.
The electric heating elements use more electricity than
heat pumps and cost more to operate.
Do Not Operate the Air Conditioner (cool mode) in Freezing Outdoor Conditions
Air conditioners are not designed for use when freezing outdoor conditions exist. They must not
be used in freezing outdoor conditions.

Quick Heat Recovery

Activates each time the thermostat is switched from OFF or COOL mode to HEAT mode. Electric heaters are energized
until the thermostat set point is reached. The heat pump operation will resume at the next call for heat.
4
not designed for AZ9V models. Refer to the operating
instructions of the thermostat being used on how to
control the unit.
There is a 3-minute minimum compressor run time at any
setting to prevent short cycling.
The fans start before the compressor and stop after the
compressor cycles off.
When the outdoor temperature is determined to be too
cold, heat is provided by the electric heater instead of by
the heat pump.
49-5000640 Rev. 1