4.6

Technical specifications

Control unit
Parameter
General specifications
Dimensions housing (W x H x D)
Weight
Housing strength
Response delay
Emissions alarm sound
Ambient conditions
Ambient temperature operation
Ambient temperature storage (without
battery)
Relative humidity
Atmospheric pressure
Electrical data
Supply voltage part number 40890
Supply voltage part number 40894
Battery (optional)
Nominal power 230 V version
Nominal power 24 V version
Relay output: breaking capacity
Maximum inrush current relay
Relay fuse
14
Product description
AFA 11
Value
100 x 188 x 65 mm
0.5 kg
IK06 impact test 1J impact energy
Test with steel ball 500 g
< 2 seconds
Min. 70 dB(A)
A-weighted sound level of the audi-
ble alarm at a distance of one metre
-5 ... 40 °C
-10 ... 60 °C
< 80 % (non-condensing)
0.08 MPa (0.8 bar) ... 0.11 MPa
(1.1 bar)
AC 100 ... 240 V, 50 ... 60 Hz
AC 15 ... 24 V, 50 ... 60 Hz or
DC 15 ... 24 V
ZnC (zinc carbon),
9V monobloc battery
Eco: 1.5 W,
FailSafe: 2.5 W
Eco 1 W,
FailSafe 1.5 W
10 A, AC 250 V, DC 30 V
14 A
2 A T