Operation; Control Panel; Functions; Ice Delay - Manitowoc CrystalCraft Premier Manual De Instalación, Operación Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Control Panel

Repeat Daily
2
Power

Ice Delay

FUNCTIONS

Power Button (Blue)
Pressing the "Power" button once will energize the ice
machine and blue Power light. Pressing the "Power" button a
second time will de-energize the ice machine.
Clean (Blue)
Pressing the "Clean" button will initiate a clean cycle and
energize the clean light. The clean light will flash during the
clean cycle to indicate the proper time to add ice machine
descaler or sanitizer.
Replace Filter (Red)
When the ice machine completes 8000 freeze/harvest
cycles the light will energize to indicate the filter needs
replacement. Depressing the "Clean" button for 6 seconds
will reset the counter and de-energize the light.
Service (Red)
Flashes to indicate a service limit has been exceeded.
Pressing the service light allows viewing of service limits.
Part Number 000016662 Rev Rev 01 01/22
Hours
4
8
Clean
Section 3

Operation

ICE DELAY
Pressing the "Ice Delay" button will initiate a delay cycle. The
ice machine will not run until the delay time expires.
Press to
Reset
Water Filter
NOTE: The power button must be on to adjust delay start.
Service
• Pressing the button once will energize the 2 hour light
and initiate a two hour delay period.
• Pressing the button a second time will energize the 4
hour light and initiate a four hour delay period.
• Pressing the button a third time will energize the 8 hour
light and initiate an eight hour delay period.
• Pressing the button a fourth time will cancel the delay
cycle.
REPEAT ICE DELAY PERIOD EVERY 24 HOURS
1. Press the power button to start the ice machine.
2. Press and hold the ice delay button for 3 seconds.
3. Pressing the ice delay button will energize the 2 hour
light and initiate a two hour delay period every 24 hours.
4. Pressing the ice delay button again will energize the 4
hour light and initiate a four hour delay period every 24
hours.
5. Pressing the ice delay button again will energize the 8
hour light and initiate an eight hour delay period every
24 hours.
6. Pressing the ice delay button again will cancel the 24
hour repeat delay. Start with step 1 to reenter 24 hour
delay setup.
EXAMPLE
Setting a daily 4 hour ice delay from 1 pm to 5 pm.
At 1 pm perform steps 1 through 4 above. The 4 hour delay
light will blink every 3 seconds to indicate it is in a delay
period. After 5 pm the ice machine will fill the bin as needed.
At 1 pm on all following days the ice machine will initiate a
delay period at 1 pm and flash the 4 hour delay LED.
Canceling a delay period
A delay period can be ended by pressing the power button
off/on.
Canceling a 24 hour ice delay period
• Press the power button while a delay period is active.
• Follow "Repeat Delay Period every 24 Hours" to step 6.
15
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Use0050

Tabla de contenido