Specific information

► Only cold water of drinking water quality may be used to supply the system.
► When supplying with softened water, only use filters for drinking water with > 4° dH total hard-
en
ness.
► Store components in a dry location.
► The system must not come into contact with chemicals, solvents, or any fumes.
► Before the filter system is put into operation, the consumer unit supplied must be free from limes-
cale.
► No copper pipes or galvanized / nickel-plated pipes or connecting parts may be installed between
the filter system and the consumer unit.
► The filter cartridge must not be opened or mechanically damaged.
► Water that is already microbiologically contaminated or of unknown microbiological quality may
not be used under any circumstances without sufficient disinfection before or after the filter.
► The filter head and the wall bracket must be replaced after 5 years of use / at the latest 6 years
after the production date. This also applies to hoses and seals. Pay attention to the date of the
production stamp.
► All components must be installed in accordance with country-specific guidelines. DIN 1988 must
be observed for the assembly and operation of the system.
► If the system pressure is greater than 8 bar, a pressure reducer must be installed upstream of the
filter system.
► The sensor unit must not be exposed to any mechanical loads. Pay particular attention to the
lever effect of hoses and bend radii. If necessary, provide support for supply lines!
► Only use commercially available AA batteries (2 x) for the sensor unit.
► Ensure that the battery cover of the sensor unit is properly closed. Otherwise, foreign objects or
moisture could penetrate.
2.5
Authorized persons
Installation and maintenance of the filter systems may only be carried out by trained and authorized per-
sonnel.
Operation and maintenance of the equipment may only be performed by trained personnel.
Any repairs not described in these operating instructions may only be performed by a qualified electrician.
3

General description

3.1
Assemblies and functional elements
See Fig. 1 (on inside cover)
1
Programming and display unit
2
Filter head with wall bracket
3
Inlet
4
Outlet
5
Purge/relief valve
6
Flushing connection with flushing hose
7
Blending levels
3.2

Scope of delivery

1 Filter head with flushing hose
1 Connection hose
2 Adapters incl. gaskets
1 Filter cartridge M for POWER steamer water softener
1 Flowmeter (items 1, 10, 11, 12) for POWER steamer water softener
1 Operating instructions
Test strips for determining the water hardness
3.3
Accessories
Information on accessories and how to use them is provided in the instructions for use available online.
8
Filter cartridge
9
Key for blending adjustment
10 Sensor unit
11 Holder for programming and display unit
12 Wall bracket for programming and display unit
13 Adapters (2 x)