Dtect200C_2610067510_06-21.qxp_D-tect200 6/14/21 9:30 AM Page 21
▪ <Language>: Select the language used in the
▪ <Date & time>: You can set the date and
display.
time for saving images, and select the date
and time format. Change the button cell
(see "Inserting/changing the button cell (see
figure C)", page 14) when the time and date
▪ <Measurement unit>: Select the unit of
can no longer be saved.
measurement for the measuring indicators.
Cause
Detection tool cannot be switched on
Battery pack or batteries empty
Detection tool cannot be connected to a PC via USB.
Detection tool not recognized by PC.
USB Type-C® port (4) or USB
cable (21) faulty
If the info/help symbol is shown on the display above the right-hand function button (6), you can access
context-related information and help by pressing the right-hand function button (available when
changing wall type and view, as well as in all measuring modes of the <Object Detection> and in the
<Leakage Detection>).
Check the detection tool each
time before use. In case of
visible damage or loose components inside the
detection tool, safe function can no longer be
ensured.
Keep the detection tool clean and dry at all times
to ensure proper and safe working conditions.
Do not immerse the detection tool in water or
other fluids.
Wipe away debris or contamination with a dry,
soft cloth. Do not use cleaning agents or solvents.
If the detection tool should fail despite the care
taken in manufacturing and testing procedures,
repair should be carried out by an authorized
Operating Instructions
▪ <Factory reset>: You can reset all of the
– <Device info>
Here you will find device information, such as
the
information.
Trouble Shooting
Corrective measures
Charge the battery pack or change the batteries.
Check whether the driver on your PC is up to date. It
may be necessary to have a newer operating system
version on your PC.
Check whether the detection tool can be
connected to a different USB cable or a different
PC. If it cannot, send the detection tool to an
authorized Bosch after-sales service center.
Maintenance and Service
service center for Bosch power tools. Do not open
the detection tool yourself.
In all correspondence and spare parts orders,
please always include the 10-digit article number
given on the type plate of the detection tool.
Store and transport the detection tool only in the
supplied protective pouch.
In case of repairs, send in the detection tool
packed in its protective pouch (22).
DISPOSAL
Detection
packaging should be sorted for environmental-
friendly recycling.
-21-
menu
options
to
Simultaneously, all of the saved images will
be permanently deleted.
installed
software
tool,
batteries,
factory
settings.
version
and
legal
accessories
and