 The unit is charged with a slightly inflammable refrigerant, R32. Improper handling of this
gas may expose people and materials to serious damage. More details on this refrigerant are given at
the beginning of this manual.
Earthing
1. The air conditioner is a Class I appliance. The unit must be earthed with an appropriate device
by a qualified technician.
may result.
2.
The green-yellow wire of the air conditioner is the earthing wire and may not be used for other
purposes.
3.
The earth resistance must meet national standards for electrical safety.
4.
The unit must be positioned so that the plug is accessible.
5. An all-pole isolating switch with a minimum contact gap of 3mm in each pole must be connected
to the fixed cable.
6.
Insert a switch with sufficient power and observe the following table. The air switch must include
a magnetic and thermal function for protection against short circuits and overloads. (Warning:
do not use only the fuse to protect the circuit).
ARGO DUAL 14 DCI R32 – ARGO DUAL 18 DCI R32
V 07/21
Ensure the unit is always properly earthed. Otherwise electric shock
Air conditioner
14-18K
21-24-28K
Air switch capacity
16A
25A
30