Fault
The high-pressure
pump repeatedly
switches on and off
without squeezing the
spray gun trigger.
The working pressure
fluctuates or drops.
The shape of the
water jet has chan‐
ged.
Detergent additive is
not being drawn in.
Connections with
pressure washer,
high-pressure hose,
spray gun or spray
lance are stiff.
17.2

Lubricating the seals

1
1
► Grease the seals (1) with grease for fittings.

18 Specifications

18.1
STIHL RE 80.0 X high-pres‐
sure cleaner
Version 100 V / 50-60 Hz
– Fuse (characteristic "C" or "K"): 15 A
– Power consumption: 1.4 kW
– Electrical protection class: II
– Degree of of electrical protection: IPX5
– Working pressure (p): 6.7 MPa (67 bar)
– Max. permissible pressure (p max.): 10 MPa
(100 bar)
44
Cause
There is a leak in the high-pressure
pump, high-pressure hose or spray
attachment.
There is not enough water.
The nozzle is blocked.
The water intake screen or water filter
is blocked.
The high-pressure pump, high-press‐
ure hose or spray attachment is lea‐
king or faulty.
The nozzle is blocked.
The nozzle is worn.
The container is empty.
The nozzle of the spraying set is
blocked.
The gaskets of the connections have
not been greased.
1
Remedy
► Clean the nozzle.
► Ask a STIHL servicing dealer to
inspect the pressure washer.
► Open water tap fully.
► Make sure that a sufficient quantity
of water is available.
► Clean the nozzle.
► Clean water intake screen and water
filter.
► Ask a STIHL servicing dealer to
inspect the pressure washer.
► Clean the nozzle.
► Fit a new nozzle.
► Fill container with detergent.
► Clean nozzle of spraying set.
► Lubricate the gaskets.
– Max. water supply pressure (p in max.): 1 MPa
(10 bar)
– Max. water throughput (Q max.): 7.5 l/min
(450 l/h)
– Minimum water throughput (Q min.): 5.4 l/min
(320 l/h)
– Max. suction lift: 0.5 m
– Max. water temperature in pressure mode
(t in max): 40 °C
– Max. water temperature in suction mode:
20 °C
– sample inspection
– Length: 250 mm
– Width: 270 mm
– Height: 430 mm
– Length of high-pressure hose: 5 m
– Weight (m) with accessory attached: 7 kg
Version 120 V - 127 V / 60 Hz
– Fuse (characteristic "C" or "K"): 15 A
– Power consumption: 1.5 kW
– Electrical protection class: II
– Degree of of electrical protection: IPX5
– Working pressure (p): 7 MPa (70 bar)
– Max. permissible pressure (p max.): 10 MPa
(100 bar)
18 Specifications