too low and the tool will not operate. In this situation, remove
and recharge the Battery.
6.TROUBLESHOOTING
1. WHY DOES THE DRILL NOT TURN ON WHEN YOU
PRESS THE SWITCH?
The Forward/Reverse Rotation Control, which is on top
of the On/Off Switch, is positioned in the lock function.
Unlock the Forward/Reverse Rotation Control by
putting it into the required rotation position. Push the
On/Off Switch and the drill will start to rotate.Check
that the battery is charged and properly connected to
the tool.
2. THE DRILL STOPS BEFORE THE SCREW IS
16
COMPLETELY TIGHTENED. WHY?
Verify the torque position of the torque adjusting ring.
Find the torque adjusting ring between the chuck and
the drill body. Position 1 is the lowest torque (screw
driving force) and position 20 is the highest torque
(screw driving force). Position
Regulate the torque adjusting ring to a higher position
to reach the best result.
3. REASONS FOR DIFFERENT BATTERY PACK
WORKING TIMES
Charging time problems, as above, and having not
used a battery pack for a prolonged time will reduce
the battery pack working time. This can be corrected
is for drill operation.
after several charge and discharge operations by
charging & working with your drill. Heavy working
conditions such as large screws into hard wood will
use up the battery pack energy faster than lighter
working conditions. Do not re-charge your battery
pack below 0°C and above 40°C as this will affect
performance.
7.MAINTENANCE
Remove the Battery Pack from the tool before
carrying out any adjustment, servicing or
maintenance.
Your tool requires no additional lubrication or
maintenance.
There are no user serviceable parts in your power
tool. Never use water or chemical cleaners to clean
your power tool. Wipe clean with a dry cloth. Always
store your power tool in a dry place. Keep the motor
ventilation slots clean. Keep all working controls free
of dust. Occasionally you may see sparks through the
ventilation slots. This is normal and will not damage
your power tool.
FOR BATTERY TOOLS
The ambient temperature range for the use and
storage of tool and battery is 0
C-45
C .
o
o