Spare Parts; Disposal Information - Renfert POWER steamer 1 Guia De Inicio Rapido

Ocultar thumbs Ver también para POWER steamer 1:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Only perform descaling if the pressure tank has completely cooled down.
Do not operate the unit during descaling. This could cause dissolved particles of calcium deposit
en
to enter the pipes and equipment, e.g., the solenoid valve, and lead to failure of the unit.
Regular removal of sludge and loose calcium deposits by rinsing reduces the need to use chemicals.
However, it is not possible to entirely prevent a layer of calcium from forming.
If the unit detects calcification despite rinsing or shortly after rinsing, the pressure tank should be de-
scaled as soon as possible.
⇒ Disconnect the unit from the mains power supply and allow it to cool down.
⇒ Rinse the pressure tank with water and using a cleaning brush until the water runs clear and/or no fur-
ther large pieces of calcification crust are discharged from the service opening.
⇒ Close the service opening.
⇒ Fill the water tank with 1 l of water.
⇒ Then fill with 1 l of Renfert descaling solution.
Caution: Danger of chemical burns/corrosion due to descaling solution spraying out.
Depending on the existing amount of calcium deposits, a strong chemical reaction can occur
causing bubbles and foam to develop.
This can cause the descaling solution to spray out.
Do not refill more than the specified quantity of water.
⇒ After approx. 15 minutes, slowly fill the unit with a further 0.6 - 0.8 liters of water. If foam develops, only
continue to fill after the foam has subsided.
⇒ Allow the descaling solution to soak in.
Recommended exposure time: 2 - 4 hours
⇒ After the exposure time has come to an end: carefully open the service opening and drain the descaling
solution.
Caution: The descaling solution is corrosive! In the event of skin contact, rinse immediately with
water.
Observe the safety data sheet.
⇒ Rinse the pressure tank several times with water and brush out using the cleaning brush until the water
runs clear and/or no further large pieces of calcification crust are discharged from the service opening.
If the resulting descaling is not sufficient, repeat the procedure.
⇒ Close the service opening again.
Checking the overpressure valve
The correct function of the safety valve must be checked once a year by a specialist.
The safety valve can be accessed at the rear of the unit.
A corresponding description is provided in the operating instructions, which you can download from our
website at

Spare parts

You can find wear parts and spare parts in the spare parts list available online at
www.renfert.com/p918.
Enter the following item number: 18450000 or 18460000.
The components excluded from the warranty (wear parts, consumables) are
marked in the spare parts list.
The serial number, date of manufacturing and equipment version are shown on
the nameplate of the equipment.

Disposal information

For this reason, equipment with this symbol may not be disposed of in unsorted domestic waste
within the European Union.
Please contact your local authorities for more information on proper disposal.
www.renfert.com/p918