Graymills DMS332 Instrucciones De Operacion Y Mantenimiento página 9

Limpiador de piezas montado en tambor – solvente
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

FIG.
3
Drum Mount Pump
The pump (FIGURE 2(D)) is a valuable aid in parts cleaning. It is particularly useful for flushing away
softened grease and grime as you brush the parts. The pumps designed for the Drum Mount models
operate at low pressure to aid against splash. These pumps are made of high strength, reinforced
thermoplastic. The pump screen which protects the pump intake may need periodic cleaning.
Never work with equipment you feel may be unsafe. Contact your supervisor immediately if you
feel a piece of equipment is in an unsafe condition.
Fill tank with Graymills Regular Agitene® 141/Super Agitene® 141 or comparable cleaning fluid
with a flash point of 104°F (40°C) or higher. Drum must contain enough fluid to submerge the
pump (FIGURE 2(D)) but should not be filled above top drum bead.
Insert plug into a properly grounded compatible outlet.
This machine contains a flexible hose (FIGURE 2(J)) capable of splashing solvent and/or ejecting
it from the machine. The hose must be directed into the tank at all times and eye protection worn
while operating the equipment.
Turn on rocker switch on right side of tank to start fluid recirculating.
When DMS tank is removed from reservoir, care must be taken not to damage pump. Lift tank straight
up and lay upside down.
The light (DMD only) has a switch located on top making it possible to operate pump with light off.
795-93850
9 of 41
12/15/21
Tabla de contenido
loading

Este manual también es adecuado para:

Dms336Dmd332Dmd336

Tabla de contenido