Graymills DMS332 Instrucciones De Operacion Y Mantenimiento página 10

Limpiador de piezas montado en tambor – solvente
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Cleaning
Inspect pump, fusible link, and all electrical cords and plugs each time unit is cleaned. Do NOT use if any
wear or damage is noticed until impaired components are repaired or replaced.
Fill drum to recommended operating capacity range before plugging in power cord. (See INSTALLATION
AND OPERATION section).
To maximize fluid life and increase efficiency of the unit, the unit should be cleaned regularly. It is
recommended that the unit's metal strainer and cloth filter bag located at the bottom center of the tank
be removed and cleaned daily for optimum filtration of contaminants and lengthened fluid life.
Changing Fluid
When it is determined that the cleaning fluid is no longer usable, remove the tank from the drum, dispose
of the contents in accordance with local regulations, wipe out drum and refill with fresh cleaning fluid. To
avoid buildup of sludge and grime, periodically wipe out tank.
Always dispose of used cleaning fluid properly. Refer to the cleaning chemical manufacturer's package
label and solvent MSDS for instructions.
DMD Models Only
The pump supplied with this parts cleaner is retractable to protect it as well as to facilitate fluid
changeovers.
Raise pump by pulling cable straight out as far as it will go. Be sure to pull the cable straight out
of the hole in order to avoid scraping cable against sleeve opening (see Figure 3). Repeated
scraping will cause cable to fray and weaken.
Swing the cable over to opposite end of tank and insert into holding bracket. This will secure pump
into circular ring. Pump DOES NOT hang down, and therefore lift is much less.
Wiring Schematic
795-93850
MAINTENANCE
10 of 41
12/15/21
Tabla de contenido
loading

Este manual también es adecuado para:

Dms336Dmd332Dmd336

Tabla de contenido