POSITIONING FOR GAS HOB
This unit may be installed and used only in permanently ventilated rooms
according to the current laws.
The following requirements must be considered:
• The room must be fitted with a ventilation system which ventilate smoke and
gases from combustion to the outside of rooms. This must be done by a cooker
hood or electric ventilator.
• The room must be allowed for the influx of the air which for proper combustion.
The air flow for combustion purposes must not less than 2 m³/h per kW of
installed capacity. The air supply will be effected by influx from the outside
through a duct, its inner cross section is at least 100cm² and must not be
blocked accidentally. The gas hob without safety devices, to prevent flame go
out accidentally, must have a ventilation working on twice volume. For example,
a minimum of 200 cm² (Fig. 3) Otherwise, the room can be vented indirectly
through adjacent rooms which is fitted with ventilation ducts to the outside. Al
though the adjacent rooms are not shared areas, bedrooms, but fire risk is
hidden (Fig. 4).