5.3 Trouble shooting
The lift trolley is designed for safe and efficient operation, provided that routine maintenance is
carried out in accordance with the instructions given. If problems arise, some guidance is provided
below. If the problem persists after action has been taken – Please contact service technician.
If the load carrier does not move at all, or very slowly:
Verify that the maximum load is not exceeded.
Charge the batteries.
Check that the battery charger works. A light should be visible on the charger when plugged
into the mains power.
Check if the fuse inside the power pack needs to be replaced.
Check the battery voltage and replace batteries if the voltage after 8 hours of charging is
less than 25 volts.
If the lift trolley sounds strange:
Make sure the lift trolley is correctly assembled, see section Assembly.
See section Maintenance.
6 Technical specifications
Model
Maximum load
Batteries
Nominal battery voltage
Mains voltage
Noise
Vibration
Test factor for static testing
________________________________________________________________________________
Minilift 65
Minilift 85
65 kg
85 kg
9 – Minilift 65 / 85 / 120
Minilift 120
120 kg
Vented lead batteries
24 V DC
230 V AC 50 Hz or 115 V AC 60 Hz
The noise level does not exceed 70 dB(A)
Vibrations do not exceed 2.5 m/s
1.25
2