Daikin EKHHE200CV37 Manual De Usuario, Instalacion Y Mantenimiento página 6

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 134
SERVICING - MAINTENANCE - TROUBLESHOOTING WARNINGS
Any repairs, maintenance, plumbing and electrical connections must be done by qualified
technicians using original spare parts only. Failure to observe the above instructions can
compromise the safety of the appliance and relieves the manufacturer of any liability for the
consequences.
To empty the appliance: turn off the power supply and cold water, open the hot water taps and then
operate the drain valve of the safety device.
The pressure relief valve must be operated regularly to remove scale deposits and to ensure that
it is not blocked.
The appliance is equipped with a supply cord that if damaged, must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
The appliance incorporates a time-Iag miniature fuse-link that if broken, it must be replaced with
a fuse model "T5AL250V" in accordance with IEC 60127.
Refer to description and illustrations, respectively, in the "TROUBLESHOOTING" chapter 9 and
"MAINTENANCE" chapter 10.
Page 6
User, Installations and Maintenance Manual
Tabla de contenido
loading

Este manual también es adecuado para:

Ekhhe200pcv37Ekhhe260cv37Ekhhe260pcv37

Tabla de contenido