PATTERN

This is a replay function so that the MANUAL functions such as PAN, TILT, ZOOM,
and FOCUS are played for 30 seconds.
** MAIN MENU **
CAMERA...
VIDEO SET...
PRESET...
AUTO MODE...
ALARM SET...
OTHER SET...
PATTERN can be set to 3. Choose 1, 2, or 3 with the left or right key in the "PATTERN
SET" and press [ENTER] to get into the PATTERN set up screen.
From the moment "PATTERN 1 SET" is gone for 30 seconds, it memorizes the
MANUAL movements and after 30 seconds it will return to a higher menu.
If you want to finish set up before the 30-second ends, press [ENTER].
3-20
All manuals and user guides at all-guides.com
(AUTO MODE)
AUTO PAN
...
Press
PATTERN SET
1...
[Enter]
RET
PATTERN1 SET
Press
[Enter]
ALARM SET
It consists of 4 ALARM INPUTs and 3 ALARM OUTs.It can sense an ALARM input from
exterior SENSORs and it performs with PRESET or PATTERN function and outputs the
ALARM OUT signals.
It recognizes the ALARM signal input as an ALARM signal when it continnes more than
150ms for a time and each ALARM movement time is decided depending on it's
correspondence to the DWELL TIME of the PRESET and PATTERN connected.
** MAIN MENU **
CAMERA...
VIDEO SET...
Press
PRESET...
AUTO MODE...
[Enter]
ALARM SET...
OTHER SET...

ALARM PRIORITY SET

Sets the priority of the 4 ALARM inputs and corresponds to
priority.The priority of the DEFAULT is ALARM1: 1, ALARM2:
2, ALARM 3: 3, ALARM: 4.If the ALARM is working at the
same time and the priority is the same, it will operate
according to the DEFAULT priority.While the ALARM is
working, it cannot detect MOTION.
ALARM IN SET
Set the TYPE to "NO" (Normal Open), "NC" (Normal Close),
or "OFF" depending on the features of the SENSOR
connected.
( ALARM SET)
ALARM PRIORITY SET..
ALARM IN SET..
E
ALARM OUT SET..
ALARM PATTERN SET..
AUX OUT CONTROL..
RET
ALARM PRIORITY
ALARM1
1
ALARM2
2
ALARM3
3
ALARM4
4
EXIT
QUIT
ALARM IN
ALARM1
NO
ALARM2
NC
ALARM3
NO
ALARM4
NC
EXIT
QUIT