Main Supply
Voltage
Current type
Connected load
Protection (slow)
Maximum allowed net impedance
Water connection
Max. feed temperature
Min. feed volume
Suck height from open container
(20 °C)
Max. feed pressure
Performance data
Water flow rate
Operating pressure of water (using
standard nozzle)
Max. excess operating pressure (safety
valve)
Steam flow rate
Max. operating pressure for working
with steam (using steam nozzle)
Part no. of steam nozzle
Max. operating temperature of hot wa-
ter
Working temperature steam operation °C
Detergent suck in
Burner performance
Max. recoil force of hand spray gun
Nozzle size
Values determined as per EN 60355-2-79
Noise emission
Sound pressure level L
Uncertainty K
pA
Sound power level L
WA
K
WA
Hand-arm vibration value
Hand spraygun
Spray lance
Uncertainty K
Fuel
Fuel
Amount of oil
Oil grade
Dimensions and weights
Length x width x height
Weight without accessories
Fuel tank
Detergent Tank
Technical specifications
V
Hz
kW
A
Ohm
°C
l/h (l/min)
m
MPa (bar)
l/h (l/min)
MPa (bar)
MPa (bar)
l/h (l/min)
MPa (bar)
--
°C
l/h (l/min)
kW
N
--
dB(A)
pA
dB(A)
+ Uncertainty
dB(A)
m/s
2
m/s
2
m/s
2
--
l
--
mm
kg
l
l
220/230
1~ 50
3,2
16
550 (9,2)
530 (8,8)
13 (130)
13 (130)
Fuel oil EL or Diesel
Engine oil 15W40 (6.288-050)
– 13
EN
HDS 551 C Eco
240
240
1~ 50
1~ 50
3,2
3,0
15
13
(0.328+j 0.205)
30
700 (11,7)
0,5
0,6 (6)
530 (8,8)
12 (120)
14,3 (143)
--
--
--
98
--
0-20 (0-0,3)
47
24
036
77
2
93
2,6
2,3
1,0
0,5
940 x 600 x 740
80
16
8
220
1~ 60
3,2
16
530 (8,8)
13 (130)
37