4-4-3.Tone Tracing on Coax Cable Cont
The tone can be sent through the center conductor, the shield or both.
•
Repeatedly press the Cycle Button to select the desired conductors.
•
The selection will be shown on the bottom of the display, refer to sequence
•
chart below for explanation.
Note: Applying the tone on the center conductor and the shield or just the shield will allow the
tone to be detected at a greater distance from the cable. When trying to identify a cable in the
presence of multiple cables, sending the tone through just the center conductor will limit the
signal spreading to other cables. The cable that is being toned can be identified by touching the
probe tip to the center conductor at the end of the cable.
S
Shield
Center Conductor
C
Center Conductor
and Shield
VDV Wire Tester
CS
23