Cebora EVO 260 T Manual De Instrucciones página 49

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Error
in
reading
22
authentication code.
EPLD Fault.
25
Primary current excessive.
30
Incorrect trimmer set on control board.
Encoder error (excessive difference between
42
set point and measured speed).
trG
Start
command
(53)
overtemperature alarm reset.
Time-out max. Short circuit lasting time
56
excessive.
Mot
Excessive error wire feeder motor current.
(57)
58
Firmware versions misalignment error.
bAd cfg
EEprom inconsistent configuration error.
(59)
L1 mains phase voltage lower than minimum
61
allowed value.
PLU nc
Plasma Welding Console not connected.
(70)
tH1
Power board igbt group overtemperature.
(74)
H2O
Cooling liquid pressure low.
(75)
H2O nc
Cooling Unit not connected.
(76)
rob
Emergency stop by Robot, or Robot off.
(90)
OFF
Mains supply missing (Power Source power
(99)
off)..
3300036-C
the
hardware
key
Check the wiring between control board and hardware key.
Replace control board and/or hardware key.
Replace control and/or power boards.
Replace power transformer and/or secondary diode group.
Perform trimmer adjusting procedure on control board, following
Power Source Service Manual instructions. Replace control board.
Replace encoder or wire feeder motor and/or motor control board.
present
at
the
Remove start command.
Replace control board.
Check torch wearing conditions, power wiring between diode group
and Power Source output terminals.
Replace control and/or power boards and/or current transducer.
Replace wire feeder motor or wire feeder group and/or motor control
board.
Update the firmware of the Power Source and other equipments
connected on CAN-1 line. Replace control board.
Replace control board.
Make sure the mains three phases values.
Replace precharge and/or control and/or power boards.
Check the CAN bus connection between control board and Plasma
Console. Check compatibility versions of the programs included in
the boards. Replace control board and/or Plasma Console.
Replace temperature sensor on igbt group and/or control board.
Check the wiring between precharge board, BR connector on Power
Source rear panel and pressure switch on Cooling Unit.
Replace pressure switch and/or precharge and/or control boards.
Check the wiring between precharge board and BQ connector on
Power Source. Make sure the presence of a jumper between pins 1
and 2 of the Cooling Unit connector.
Replace precharge and/or control boards.
Check Power Source - Robot connections and Robot power supply
and/or plant safety conditions.
Replace precharge and/or control boards.
G
B
49
Tabla de contenido
loading

Este manual también es adecuado para:

Evo 330 tEvo 450 t369.80370.80371.80

Tabla de contenido