OBJ_DOKU-32899-004.fm Page 15 Friday, August 19, 2016 3:25 PM
Technical Data
Pneumatic straight screwdriver
Article number
-1
No-load speed
min
Output power
W
Maximum torque
Nm
Max. screw diameter
mm
Right/left rotation
Tool holder
– Quick-change chuck
mm
Thrust-start
Shut-off clutch
Max. working pressure for
bar
tool
psi
Thread size of hose
connection
Inner diameter of hose
mm
Air consumption at no-load
l/s
cfm
Weight according to EPTA-
kg
Procedure 01:2014
lbs
Assembly
Devices for Safe Handling
Pneumatic tools that are operated with a torque > 4 Nm, must
be equipped with an auxiliary handle or fastened in a clamping
fixture via the clamping area 4.
If you want to operate the pneumatic tool in a suspension
device or a clamping fixture, take care to fasten it in the
device/fixture first before connecting it to the air supply.
This measure prevents accidental starting of operation.
Make sure that the auxiliary handle or the clamping fixture
holds the pneumatic tool securely and firmly.
Do not overload the clamping area.
Suspension Device
With the utility clip 6, you can fasten the pneumatic tool to a
suspension device.
Regularly check the condition of the utility clip and the
hook of the suspension device.
Clamping Fixture
– The pneumatic tool can be mounted in a clamping fixture
over the mentioned clamping area 4. If possible, utilise the
entire clamping area. The smaller the clamping area, the
stronger the clamping forces act.
Auxiliary Handle
– Slide the auxiliary handle 8 onto the clamping area (collar) 4.
The auxiliary handle 8 can be set to any position for a secure
and low-fatigue working posture.
– Turn the wing bolt for adjustment of the auxiliary handle in
anticlockwise direction and set the auxiliary handle 8 to
the required position. Then tighten the wing bolt again in
clockwise direction.
Bosch Power Tools
Exhaust-air Guidance
With exhaust-air guidance, the exhaust air can be diverted
0 607 461 ...
through an exhaust-air hose away from your workplace, while
... 205
... 206
at the same time achieving optimal sound-proofing. Addition-
1050
700
ally, your working conditions are improved, as your workplace
400
400
can no longer be contaminated though oil-containing air and
dispersed dust or chips.
5.5–10
5.5–15
Centralised Exhaust-air Guidance (see figure A)
M 6
M 8
– Loosen hose clamp 10 of supply-air hose 11, mount the
supply-air hose to hose fitting 7 and retighten the hose
clamp.
1/4"
1/4"
– Work the exhaust-air hose (centralised) 9, which conducts
the exhaust air away from your workplace, over the supply-
air hose 11. Then connect the pneumatic tool to the air
supply (see "Connecting the Air Supply", page 15) and
6.3
6.3
work the exhaust-air hose (centralised) 9 over the mount-
91
91
ed supply-air hose onto the end of the pneumatic tool.
Connecting the Air Supply
G 1/4"
G 1/4"
For maximum performance, the values for the inner hose di-
10
10
ameter as well as the connection threads must be adhered to
14
14
as listed in the "Technical Data" Table. To maintain the full
29.7
29.7
performance, only use hoses with a maximum length of 4 m.
1.4
1.4
The compressed air supplied should be free of foreign materi-
3.1
3.1
al and moisture to protect the tool from damage, contamina-
tion, and the formation of rust.
Note: The use of a compressed-air maintenance unit is neces-
sary. This ensures proper function of the pneumatic tools.
Observe the operating instructions of the maintenance unit.
All fittings, connecting lines and hoses must be dimensioned
for the pressure and the required air volume.
Avoid restrictions in the air supply, e.g., from pinching, kink-
ing, or stretching!
When in doubt, check the pressure at the air inlet with a pres-
sure gauge with the pneumatic tool switched on.
– For pneumatic tools with lever start, actuate the lever 10
several times before connecting the air supply.
Connecting the Air Supply to the Pneumatic Tool
(see figure B)
– Screw hose fitting 7 into the connection socket at air inlet 6.
To avoid damage to interior valve components of the pneu-
matic tool when screwing hose fitting 7 in or out, it is rec-
ommended to counter-hold the projecting connection
socket of air intake 6 with an open-end wrench
(size 22 mm).
– Loosen hose clamp 10 of supply-air hose 11, mount the
supply-air hose to hose fitting 7 and retighten the hose
clamp.
Note: Always mount the supply-air hose to the pneumatic tool
first, then to the maintenance unit.
Changing the Tool (see figure C)
– Pull the sleeve 2 of the quick-change chuck to the front and
hold.
– Place the application tool into the tool holder 1 and release
the sleeve 2.
English | 15
1 609 92A 37L | (19.8.16)