Important Informations; Instructions For Placing And Removing Gas Bottle - Jocel JAT007391 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

IMPORTANT INFORMATIONS

• LPG cylinder not provided. The appliance is designed to operate with a cylinder size
no more than Ø31.8 x 58 cm.
• This appliance requires a 15 kg butane LPG cylinder or a 13 kg propane LPG cylinder.
Gas regulator should be the correct one and be set according to specific gas category
(see Technical data on page 3).
• Gas regulator should be approved according to EN 16129:2013 with proper capacity
(g/h), pressure, working temperature and inlet + outlet connection for the country of
destination.
• The regulator illustrated on the manual is for United Kingdom, the regulator in your
country maybe different with the one on the illustration.
• Flexible gas rubber pipe should be approved according to 16436-1:2014 with proper
inner Ø to match pipe holders of gas circuit and gas regulator, pressure and working
temperature.
• The length of the hose is 1.5 m and it should not exceed 1.5 m. The hose shall be
readily visible across its entire length for inspection after installation.
• The injector in this appliance is not removable and the injector is only assembled by
manufacturer. This appliance is forbidden to convert from one gas pressure to another
pressure.
DANGER!
You must have the proper regulator and cylinder in order for the appliance
to operate safely and efficiently. Use of an incorrect or faulty regulator is
dangerous and will invalidate any warranty.

INSTRUCTIONS FOR PLACING AND REMOVING GAS BOTTLE

CONNECT LP GAS CYLINDER
1. Before connecting, be sure that there is no debris caught in the head of the LP tank,
head of the regulator valve or in the head of the burner and burner ports.
2. Connect gas line to tank by turning knob clockwise until it stops, make sure that the
tube is not subject to twisting.
3. After connecting to gas cylinder, a leak testing is necessary.
DISCONNECT LP GAS CYLINDER
1. Before disconnecting make sure the LP gas tank valve in "CLOSED". Disconnect gas
line from LP gas cylinder by turning knob counterclockwise until it is loose.
2. For storage and cylinder exchange, disconnect hose at the cylinder only, DO NOT
disconnect hose from appliance.
3. To change the gas cylinder in an amply ventilated area, away from any ignition source
(candle, cigarettes, other flame producing appliances...).
42
Tabla de contenido
loading