Application Areas / Conversion Table; Pressure Drop; Fault Conditions; Energy Consumption Data - Stiebel Eltron DCE-X 6/8 Premium Operación E Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
iNSTallaTiON
Specification
17.4 Application areas / conversion table
Electrical resistivity and electrical conductivity.
Standard specifica-
tion at 15 °C
20 °C
Conductivity σ ≤ Resis-
Resis-
tivity
tivity
ρ ≥
ρ ≥
Ωcm
mS/m μS/cm
Ωcm
1100
91
910
970

17.5 Pressure drop

Fittings
Tap pressure drop at a flow rate of 10 l/min
Mono lever mixer tap, approx.
Thermostatic valve, approx.
Shower head, approx.
Sizing the pipework
When calculating the size of the pipework, an appliance pressure
drop of 0.1 MPa is recommended.

17.6 Fault conditions

In the event of a fault, loads up to 80 °C at a pressure of 1.0 MPa
can occur briefly in the installation.

17.7 Energy consumption data

Product datasheet: Conventional water heaters to regulation (EU) no. 812/2013 | 814/2013
Manufacturer
Load profile
Energy efficiency class
Energy conversion efficiency
Annual power consumption
Default temperature setting
Sound power level
Special information on measuring efficiency
Daily power consumption
www.stiebel-eltron.com
25 °C
Conductivity σ ≤ Resis-
Conductivity σ ≤
tivity
ρ ≥
mS/m μS/cm
Ωcm
mS/m
103
1031
895
112
MPa
0.04 - 0.08
MPa
0.03 - 0.05
MPa
0.03 - 0.15
%
kWh
°C
dB(A)
Measured at ECO level with highest flow rate,
maximum output and maximum set value.
kWh
μS/cm
1117
DCE-X 6/8 Premium
238158
STIEBEL ELTRON
XS
472
60
2.161
DCE-X 10/12 Premium
A
39
15
Measured at ECO level with highest flow rate,
maximum output and maximum set value.
DCE-X Premium |
238159
STIEBEL ELTRON
XS
A
39
473
60
15
2.167
19
Tabla de contenido
loading

Este manual también es adecuado para:

Dce-x 10/12 premium238158238159