Cleaning And Maintenance; What If There Are Problems; Disposal - Beurer DS 61 Instrucciones De Uso

Ocultar thumbs Ver también para DS 61:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
• Use the number buttons to enter the energy value
of the food (in 1 kcal graduations) and confirm the
input by pressing the button MR.
Next the values for the cholesterol content (in 1 mg
graduations), the carbohydrate content (in 0.1 g
graduations), the fat content (in 0.01 g graduations)
and the protein content (in 0.01 g graduations) are
requested. After you have entered the appropriate
value, press the button MR in order to move to the
next requested value. After you have entered the
last value (for the protein content) and pressed the
button MR, the appliance switches to the weighing
mode.
Note: If you do not know a requested value of the
food, please leave the value on "0" and press the
button MR in order to enter the next value. Please
note that in your diet control the value that has
been left as "0" is not included in the addition of a
nutritional or energy value (see "Displaying added
readings").
• Please check that the entered value is plausible.
6.4 Replacing the batteries
The scale requires 3x AAA batteries. If the replace
battery symbol
appears, it means that the bat-
teries are almost empty. Insert the batteries into the
battery compartment on the underside of the scale.
Make sure that the batteries are inserted the correct
way round.
Notes on handling batteries
• If your skin or eyes come into contact with battery
fluid, flush out the affected areas with water and
seek medical assistance.
Choking hazard! Small children may swallow
and choke on batteries. Store the batteries out of
the reach of small children.
• Observe the plus (+) and minus (-) polarity signs.
• If a battery has leaked, put on protective gloves and
clean the battery compartment with a dry cloth.
• Protect the batteries from excessive heat.
Risk of explosion! Never throw batteries into a fire.
• Do not charge or short-circuit batteries.
• If the device is not to be used for a long period,
take the batteries out of the battery compartment.
• Use identical or equivalent battery types only.
• Always replace all batteries at the same time.
• Do not use rechargeable batteries.
• Do not disassemble, split or crush the batteries.

7. Cleaning and maintenance

You can clean the scale with a damp cloth, using a
little washing-up liquid if necessary.
Clean the weigh plate surface regularly.
Accuracy of readings and the instrument's service
life depend on careful handling.
IMPORTANT
• Make sure that no liquid comes onto the scales.
Never immerse the scales in water. Never rinse
them off under running water.
• Do not clean the scales in the dishwasher!
• Do not place any objects on the scales when not
in use.
• Protect the scales from impact, moisture, dust,
chemicals, major temperature fluctuations and
keep away from heat sources (ovens, radiators).
• Do not expose the scales to high temperatures
or strong electromagnetic fields (e.g. mobile tel-
ephones).

8. What if there are problems?

Display Cause
The weighing range
E----
of 5000 g has been
exceeded.
The maximum memory
of at least one of the
nutritional or energy
values has been excee-
ded, e.g. over 99999
kJ.
There is no nutritional
or energy value for this
foodstuff that has been
requested.
0 is added in memory
mode.
M is
The maximum memory
flashing
of at least one of the
nutritional or energy
values has been
exceeded, e.g. over
99999 kJ.
The battery is almost
flat.
Minus
The item to be weighed
value (-)
was placed on the
scales before they
were switched on.
No dis-
The battery is com-
play
pletely flat.

9. Disposal

For environmental reasons, do not dispose of
the device in the household waste at the end
of its useful life. Dispose of the unit at a sui-
table local collection or recycling point. Dispose of
the device in accordance with EC Directive – WEEE
(Waste Electrical and Electronic Equipment). If you
have any questions, please contact the local authori-
ties responsible for waste disposal.
19
Remedy
Remove the item to
be weighed from the
weigh plate.
Clear the memory with
memory button MC.
Clear the memory with
memory button MC.
Replace the battery in
the scale (see Chap-
ter 6.4. Replacing the
batteries).
Press the
button.
Insert a new bat-
tery (see Chapter
6.4. Replacing the
batteries).