Technical data

Machine data

Shank
dimension
Type
(mm)
CP 0012 H19
H
(19 x 50)
CP 0012 2R
Rd 0.680
(17.3)
CP 0012 2H
H 0.580
(14.7)

Noise and vibration declaration statement

Guaranteed sound power level Lw according to EN ISO 3744 in accordance with directive 2000/14/EC.
Sound pressure level Lp according to EN ISO 11203.
Vibration value A and uncertainty B determined according to EN ISO 20643. See table "Noise and vibration
data" for the values of A, B, etc.
These declared values were obtained by laboratory type testing in accordance with the stated directive or
standards and are suitable for comparison with the declared values of other tools tested in accordance with
the same directive or standards. These declared values are not suitable for use in risk assessments and values
measured in individual work places may be higher. The actual exposure values and risk of harm experienced
by an individual user are unique and depend upon the way the user works, in what material the machine is
used, as well as upon the exposure time and the physical condition of the user, and the condition of the
machine.
We, Atlas Copco Construction Tools AB, cannot be held liable for the consequences of using the declared
values, instead of values reflecting the actual exposure, in an individual risk assessment in a work place situation
over which we have no control.
This tool may cause hand-arm vibration syndrome if its use is not adequately managed. An EU guide to
managing hand-arm vibration can be found at
http://www.humanvibration.com/humanvibration/EU/VIBGUIDE.html
We recommend a programme of health surveillance to detect early symptoms which may relate to vibration
exposure, so that management procedures can be modified to help prevent future impairment.

Noise and vibration data

Type
CP 0012 H19
CP 0012 2R
CP 0012 2H
9800 0548 90b | Original instructions
Weight
in.
lb
(kg)
3
x 2
12
4
(5.5)
12
(5.5)
12
(5.5)
Noise
Declared Values
Sound pressure
EN ISO 11203
Lp
r=1m dB(A) rel
guaranteed dB(A) rel
20µPa
89
89
89
Safety and operating instructions
Length
in.
Impact freq.
(mm)
Hz
16
43
(406)
16
43
(406)
16
43
(406)
Sound power
2000/14/EC
Lw
m/s
1pW
104
104
104
Air Consumption
3
foot
/min
(l/s)
20
(9.5)
20
(9.5)
20
(9.5)
Vibration
Declared Values
Three axes values
EN ISO 20643
A
B
2
2
value
m/s
spread
14.6
1.9
14.6
1.9
14.6
1.9
17