Technical Specifications; Installation On To The Boiler - Ferroli COMPACT ECO 3 Manual Para La Instalacion Y El Mantenimento

Quemadores para gasóleo
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TECHNICAL SPECIFICATIONS

COMPACT ECO
Output
Flow
Preheater
Functioning
Fuel
Max Viscosity at 20°C
Electrical power supply
Pump calibration
Motor
Max. absorbed power
Condenser
Trasformator (voltage / secondary current)
Electric protection rating
Noise level *
60° nozzle with vacuum / half-empty cone
Weight
* Sound pressure measured in the manufacturer's combustion laboratory, with burner operating on a test boiler
and at maximum output..

INSTALLATION ON TO THE BOILER

Fix flange 2 to the boiler using 4 screws 3 interposing the insulation gasket 4 and the possi-
ble insulating cord 5. Insert the burner in the flange so that the draught tube penetrates into
the combustion chamber by the length suggested by the boiler manufacturer. Tighten screw
UK
1 to lock the burner in position.
26
3
min
14,5
max
41,5
min
1,20
max
3,50
12
100
175
6,3
15 / 40
20
61
0,6
10
5
1
4
3
2
3R
6
14,5
26,2
41,5
64,3
1,20
2,20
3,50
5,4
-
110
-
On / Off
Light oil
1,5 °E - 6 CSt - 41 sec; R1
230/50 o 60 single-phase
12
12
100
100
240
175
6,3
6,3
15 / 40
15 / 40
20
20
61
61
0,6
0,85
10,1
10
6R
26,2
kW
64,3
kW
2,20
kg/h
5,4
kg/h
110
W
V/Hz
12
bar
100
W
240
W
6,3
μF
15 / 40
kV/mA
20
IP
61
dB(A)
0,85
GPH
10,1
kg
Tabla de contenido
loading

Este manual también es adecuado para:

Compact eco 3rCompact eco 6Compact eco 6r

Tabla de contenido