klover DEA ECO 6 Manual Del Usario página 99

Ocultar thumbs Ver también para DEA ECO 6:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

"Various calibrations" (Menu M8 – 2) (Firmware H01_050515)
Parameter
Description
Pr38
Re-ignition block
Pr39
Flue gas extractor switch-off time
Pr40
Pre-loading time in ignition
Pr41
Stand-by time after pre-loading
Pr42
Extractor speed in pre-loading phase
"SET AMBIENT" ON temperature
Pr43
hysteresis
Economy switch-off delay (timer after
Pr44
reaching "SET AMBIENT")
Pr45
Power change delay
Pr46
Enabling of remote control
Pr47
Keypad block enabling
Pr48
Automatic re-ignition after blackout
Pr49
Room sensor calibration
Pr50
Preheating time
Pr51
Extractor speed in preheating time
"Pellet type" (Menu M8 – 3) (Firmware H01_050515)
Parameter
Description
Pellet loading percentage at the various
Pr54
working powers
"Chimney type" (Menu M8 – 4) (Firmware H01_050515)
Parameter
Description
Flue gas extraction speed percentage
Pr55
at the various working powers
Display writing
Measurement
RE-IGNITION BLOCK
EXTRACTOR OFF
MINUTES
IGNITION PRE-LOADING
STAND-BY AFTER PRE-
LOADING
EXTRACTOR PRE-
LOADING
DELTA AUTO
DELAY AUTO
POWER CHANGE
ENABLE REMOTE
KEYS BLOCK-EN
BLACKOUT
SENSOR OFF-SET
PRE-HEAT TIME
PRE-HEAT GASSPEED
Display writing
Measurement
PELLET LOADING
Display writing
Measurement
EXTRACTOR CHIMNEY
30
Value field
Minutes
0 – 10
Minutes
0 – 20
Seconds
0 – 255
Seconds
0 – 255
RPM
600 – 2800
°C
0.0 – 15.0
Minutes
2 – 120
Seconds
0 – 60
On – off
On – off
On – off
On – off
Seconds
0 – 60
°C
- 9 – 9
Seconds
0 – 360
RPM
500 – 2800
Value field
-
- 9 – 9
Value field
-
- 9 – 9
Database o0
5
10
0
0
2800
2.0
2
30
OFF
OFF
30
0
300
2800
Database o0
0
Database o0
0

Hide quick links:

Tabla de contenido
loading

Tabla de contenido