Wearing Parts; Troubleshooting - Oase AquaOxy 450 Instrucciones De Uso

Ocultar thumbs Ver también para AquaOxy 450:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

- English -
Storage/Winterization
● Take the air hoses out of the water and clean
● Check the unit for damage and store it in a frost-free environment.

Wearing parts

Diaphragms are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.

Troubleshooting

Issue
Unit does not run
Unit does not deliver air
Insufficient delivered
quantity
Cause
No mains voltage
Transformer defective
Diaphragms defective
Regulating valve incorrectly set
Valves soiled
Diaphragms defective
Excessive loss in the supply hoses
Regulating valve incorrectly set
Solution
Check mains voltage
Replace transformer
Replace diaphragms, clean air slots
Check settings
Clean
Exchange diaphragms
Reduce hose length to a minimum
Check settings
6