Wear Parts - Oase AquaMax Eco Twin 20000 Instrucciones De Uso

Ocultar thumbs Ver también para AquaMax Eco Twin 20000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
- EN -
S
Malfunction
Malfunction
Pump does not start
Pump does not deliver
Insufficient delivered quantity
Pump switches off after a short running time
Manual transmitter reach fades
Manual transmitter reach fluctuates
Manual transmitter without function
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Disposal of batteries
Do not dispose of batteries with the household waste. Only dispose of dead batteries by using the return system provi-
ded for this purpose.
Disposal of batteries within the European Union
As a user, you are obligated by law to return used batteries. Return is free of charge.
Either dispose of batteries through the public return and recycling systems of your municipality or community, or return
the batteries to the place where they were bought.
Batteries containing harmful substances bear the following signs:
Pb = Battery contains lead
Cd = Battery contains cadmium
Hg = Battery contains mercury
Li = Battery contains lithium
Storage/Over-wintering
The unit is frost resistant to minus 20 °C. Should you store the unit outside of the pond, clean it thoroughly with a soft
brush and water, check it for damage, then store immersed in water or filled with water. Do not immerse the power plug
in water!
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regu-
lations.

Wear parts

The impeller unit is a wearing part and does not fall under the warranty.
16
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Excessive loss in the supply lines
Excessively soiled water
Water temperature too high
Batteries too weak
Interferences through other units
Receiver positioned unfavourably
Batteries discharged or incorrectly inserted
Manual transmitter not taught-in
Receiver was reset
Remedy
Check mains voltage
Clean/check supply lines
Check running unit for ease of movement
Clean strainer casings
Reduce hose length to the necessary mini-
mum, do not use unnecessary connection parts
Check running unit for ease of movement
Clean strainer casings
Reduce hose length to the necessary mini-
mum, do not use unnecessary connection parts
Check running unit for ease of movement
Clean pump
Note maximum water temperature of +35°C
Replace batteries
Switch off other units which could interfere
(mobile phone, remote thermometer, remote
baby-sitter, ...)
Find a new position for the receiver housing. If
necessary, increase the distance to the floor
Check functions
Teach-in manual transmitter
Teach-in hand-held transmitter again
Tabla de contenido
loading

Este manual también es adecuado para:

Aquamax eco twin 30000

Tabla de contenido