Stainless steel hose clamp.
Wooden ground.
Non flammable floor protection.
Stainless steel flexible tube.
Rigid flexible pole adapter.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 4 m in length, the next larger
size will be used.
4.28. Installing a fitted boiler in a brickwork chimney can be done using flexible piping in its entirety, as indicated in
drawing 10. We must take special care when sealing the chimney and gas venting to avoid gas blowing back
during storms.
Stainless steel hose clamp.
T of 90° with outlet.
Wooden ground.
Non flammable floor protection.
Stainless steel flexible tube.
Rigid flexible pole adapter.
Anti blow-back seal.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 4 m in length, the next larger
size will be used.
When installing a flexible tube for gas outlet, be careful that this is not in contact or close to the circuit board
or combustible material.
The purger is located in the upper part of the boiler exchanger; you can access it by removing the exchanger
lid.
HEATING SYSTEM DRAINING (VERY IMPORTANT).
41
Drawing 9
Drawing 10