  • ESPAÑOL, página 32
Only nonconductive pollution occurs. Occasionally,
Pollution
temporary conductivity caused by condensation is to be
degree 2
expected.(home and office environments fall under this
category)
This device is only suitable for measurements in Pollution
degree class 2 environments.
operating environment:
temperature: 0 °C to 40 °C (32 to 104 °F)
o
humidity: < 80 % RH.
o
storage environment:
temperature: -20 °C to 60 °C (-4 °F to 140 °F)
o
humidity: < 90 % RH
o
9. Specifications
overrange: yes
9.1 DC VOLTAGE
range
200 mV
2000 mV
20 V
200 V
500 V
Overload protection: 500 V DC or AC rms
Impedance: 1M Ω
9.2 AC VOLTAGE
range
200 V
500 V
Average sensing, calibrated to rms of sine wave
Frequency range: 40-500 Hz
Overload protection: 500 V DC or AC rms
Impedance: 450k Ω
V. 02 – 04/03/2016
DVM832
Do not measure circuits that may contain voltages
resolution
0.1 mV
1 mV
10 mV
100 mV
1 V
Do not measure circuits that may contain voltages
resolution
100 mV
1 V
> 500 V
accuracy
± (1.0 % rdg + 2 digits)
± (1.2 % rdg + 2 digits)
> 500 V
accuracy
± (1.2 % rdg + 3 digits)
7
©Velleman nv