INSTALLATION – PRODUCT OPERATION
EQUIPMENT DESCRIPTION (FIG-1)
The GYSpot ArcPull 350 is a single-phase inverter welding machine with arc-pull technology making is suitable to weld
welding parts(threaded studs, internally threaded studs, insulation nails, pulling rings, rivet extraction rods, etc.) on
steel or aluminium based materials. It has a synergic mode and a manual mode.
Power source GYSPOT ARCPULL 350
1- Keypad
2- On/Off switch
3- Positive dinse connector for gun cable
4- Negative dinse connector for gun cable
5- Base for gun control cable connector
Automatic gun GYSPOT ARCPULL 350
1- Trigger
2- Electrode holder locking nut
3- Studs locking scrollwheel
4- Gun control cable connector
5- Positive dinse
INTERFACE (HMI) (FIG-2)
1- Display
2- Button G+
3- Button G
4- Button D+
POWER SUPPLY AND POWER UP
• This product is fitted with a 16 A CEE7/7 socket which must be connected to a single-phase power supply with a ear-
thed neutral between 208 V AC and 240 V AC(50 - 60 Hz). The absorbed current (I1eff) is indicated on the device, for
its maximum setting.
Check that the power supply and its protection (fuse and/or circuit breaker) are compatible with the current needed by
the machine. This equipment is designed to operate on an electrical installation equipped with a 16A curve C, D or K
curve circuit breaker.
In some countries, it may be necessary to change the plug to allow the use at maximum settings. The user has to make
sure that the plug can be reached.
• The device is switched on by pressing the « I » on/off button.
• The device will activate protection mode if the power supply voltage is over 265 V AC. If this is the case, the machine
displays POWER DEFAULT. Normal functioning will resume once the power supply is under 265V.
WORKING OFF A GENERATOR
The machine can work with generators as long as the auxiliary power matches these requirements:
• The voltage must be AC, always set as specified, and the peak voltage below 400 V.
• The frequency must be between 50 and 60 Hz.
• The power must be at least 15kVA.
It is imperative to check these requirements as many generators generate high voltage peaks that can damage the
machine.
USE OF EXTENSION LEAD
This equipment can be connected to the electrical installation with an extension lead as long as it matches the following
requirements:
• Single-phase extension lead with earth conductor.
• The length must not exceed 10 m.
• The cable cross-section must not be less than 2.5 mm².
GYSPOT ARCPULL 350
6- Gas outlet for gun cable
7- Gas input connected to the bottle (15 l/min) (G1/4 D6)
8- Transport handle
9- USB port protection cap
10 - Power supply cable
6- Negative dinse
7- Gas connector
8- LED ON (green)
9- LED contact (blue)
10- LED fault (red)
5- Button D
6- Button Menu/Validate
7- Return button
EN
21