Gas Connection to Natural Gas
WARNING
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, explosion, or fire.
This installation must conform with local codes and ordinances. In the
absence of local codes, installations must conform with either the
National Fuel Gas Code ANSI Z223.1 - latest edition, or CAN/CGA-
B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
IMPORTANT: The Natural gas Conversion Kit supplied with this grill
must be used.
1. Turn off all burner control valves.
2. Turn off the main gas supply valve.
3. Disconnect 20 lb LP gas fuel tank (if present) and remove the 20 lb
LP gas fuel tank from the grill cabinet.
4. Use a Phillips screwdriver to remove the 2-piece 90° clamp
mounting bracket from the cabinet wall.
A. 4 screws
B. 2-piece 90° clamp mounting bracket
14

GAS CONVERSIONS

A
B
5. Use an adjustable wrench to remove the LP gas pressure regulator/
hose assembly from the 90° brass adapter.
A. Flexible gas hose from grill
B. 90° brass adapter
C. LP gas pressure regulator/hose assembly
6. Install the Natural gas pressure regulator onto the flexible gas hose
from the grill.
7. Check that the Natural gas pressure regulator is positioned under the
grill (as shown in the following illustration) and is not pinched or
kinked.
Use 4 screws to attach the Natural gas pressure regulator to the back of
the enclosure.
A. Natural gas pressure regulator
B. Four 5/32" x 10 mm truss head screws
1. Make gas connections.
A combination of pipe fittings must be used to connect the grill to
the existing gas line.
The 10 ft (3.0 m) PVC flexible gas supply hose design-certified
by CSA must be used.
Pipe-joint compounds suitable for use with Natural gas must be
used. Do not use Teflon
2. Connect the brass connector on one end of the 10 ft (3.0 m) PVC
flexible gas supply hose (supplied) to the Natural gas pressure
regulator (A).