English
MAINTENANCE AND INSPECTION
1. Inspecting the depressed center wheel
Ensure that the depressed center wheel is free of
cracks and surface defects.
2. Inspecting the mounting screws:
Regularly inspect all mounting screws and ensure
that they are properly tightened. Should any of the
screws be loose, retighten them immediately. Failure
to do so could result in serious hazard.
3. Inspecting the carbon brushes (Fig. 4)
The Motor employs carbon brushes which are
consumable parts.
When they become worn to or near the "wear limit",
it could result in motor trouble. When a auto-shop
carbon brush is equipped, the motor will stop
automatically.
At that time, replace both carbon brushes with new
ones which have the same carbon brush Numbers
shown in the figure. In addition, always keep carbon
brushes clean and ensure that they slide freely
within the brush holders.
4. Replacing carbon brushes (Fig. 5):
<Disassembly>
(1) Loosen the D4 tapping screw retaining the tail cover
and remove the tail cover.
(2) Use the auxiliary hexagonal wrench or small
screwdriver to pull up the edge of the spring that
is holding down the carbon brush. Remove the
edge of the spring toward the outside of the brush
holder.
(3) Remove the end of the pig-tail on the carbon brush
from the terminal section of brush holder and then
remove the carbon brush from the brush holder.
<Assembly>
(1) Insert the end of the pig-tail of the carbon brush
in the terminal section of brush holder.
(2) Insert the carbon brush in the brush holder.
(3) Use the auxiliary hexagonal wrench or small
screwdriver to return the edge of the spring to the
head of the carbon brush.
NOTE:
Make sure the end of the spring is not holding the
pig-tail.
(4) Mount the tail cover and tighten the D4 tapping
screw.
5. Maintenance of the motor
The motor unit winding is the very "heart" of the
power tool. Exercise due care to ensure the winding
does not become damaged and/or wet with oil or
water.
6. Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
CAUTION
Repair, modification and inspection of Hitachi Power
Tools must be carried out by an Hitachi Authorized
Service Center.
This Parts List will be helpful if presented with the
tool to the Hitachi Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools,
the safety regulations and standards prescribed in
each country must be observed.
9
MODIFICATIONS
Hitachi Power Tools are constantly being improved
and modified to incorporate the latest technological
advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
GUARANTEE
We guarantee Hitachi Power Tools in accordance with
statutory/country specific regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling
instruction, to a Hitachi Authorized Service Center.
NOTE
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
IMPORTANT
Correct connection of the plug
The wires of the main lead are coloured in accordance
with the following code:
Blue: -Neutral
Brown: -Live
As the colours of the wires in the main lead of this tool
may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black. The wire
coloured brown must be connected to the terminal mark-
ed with the letter L or coloured red. Neither core must be
connected to the earth terminal.
NOTE
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except The United Kingdom.
Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 99 dB (A)
Measured A-weighted sound pressure level: 88 dB (A)
Uncertainty KpA: 3 dB (A).
Wear ear protection.
The typical weighted root mean square acceleration
2
value: 4.0 m/s
.