10. Start-up
Before each start-up and especially after cleaning or repairing the unit, a check must be made that
all its elements are securely tightened.
If maintenance or repair work is to be carried out, the gun must be depressurised before work
begins (without air pressure). Should this safety measure not be observed, this may lead to
malfunctions, personal injury and accidents, which may prove to be fatal. SAGOLA S.A. does not
accept any responsibility for the consequences of any non-compliance with these safety regulations.
Open the spray width and product regulators complete-
ly (without removing these from their housing) by
turning these anticlockwise.
· Gravity/suction version: Place the pistol on a support
so that the axis of the tank is vertical. Pour the product
to apply into the tank. Until the level is a maximum of
20-25 mm below the edge of the tank.
Tighten the filler cap firmly. In the version with the
non-drip cap, tip it forward (paint up) or back (paint
down) as necessary.
Connect the gun to the compressed air network.
xtreme
Pressure
· Pressure version: When assembling the equipment,
make sure to connect the air hose to air conduits (1)
1
2
and the product hose to the product conduits (2).
Regulate product pressure to the gun by applying
SAGOLA
product pressure until this fails from 15 to 20 cm. from
6110 INOX
the gun, depending upon the product to be applied.
15-20 cm
Adjust the air pressure in hte network regulator in order to compensate for any pressure drop in
the network (estimated at 0.6 bar for each 10 m. of hose).
Adjust the air pressure in the air nozzle by operating the flow regulator until the required quality
of finish is obtained (better finishes are not obtained with higher spraying pressures and these
lead to lower performance and worse product transfer).
Position the air nozzle spraying orifices appropriately (when an imaginary line is drawn through
the 2 lugs, this must be parallel or perpendicular to the floor) Fully close the product regulator by
turning it clockwise. Turn the product regulator until the "0" coincides with the arrow; and perform
the desired application test, adjusting the product regulators and range as follows:
Open the product regulator until the appropriate amount of product comes out. Now you have the
maximum spraying width (spraying pattern). You can reduce this according to your needs by
closing the spray width regulator.
Please be sure that you put the spray gun properly by
keeping its perpendicularity to the piece to be painted
in order to achieve the maximum transfer of the
OK
sprayed product and obtain the best finishing quality.
ENGLISH