5. Cut positive (+) cable to the length required to
reach the AUX terminal of the circuit breaker
(FIGS. 17-2 and 18-3), without putting strain
on the connection. Install copper lug (Kit item)
(FIGS. 18-1 and 18-2). Then, connect to AUX
terminal on 150A circuit breaker (FIGS. 17-2
and 18-3).
6. Cut remaining positive (+) cable long enough
to reach from the circuit breaker BAT terminal
to the positive (+) battery terminal (FIGS. 16-2
and 18-3) without putting strain on the con-
nection. Install copper lugs (Kit item) on both
ends of cable (FIGS. 18-1 and 18-2). Then,
connect cable to BAT terminal on 150A circuit
breaker (FIGS. 17-2 and 18-3) and positive
(+) terminal on battery (FIG. 17-2).
7. Cut negative (-) cable to length required to
reach negative (-) battery terminal (FIG. 17-
2) without putting strain on the connection.
Install copper lug (Kit item) (FIGS. 18-1 and
18-2). Then, connect cable to negative (-)
terminal on battery (FIG. 17-2).
LIFT CORPORATION Sht. 18 of 54 DSG#
ROUTING POWER CABLES - Continued
(BARE WIRE END)
PLACING COPPER LUG & HEATSHRINK
CONNECT LONG POS (+)
CABLE FROM LIFTGATE
POWER CABLE CONNECTIONS
M-15-10
Rev. D Date: 09/21/18
COPPER LUG
HEATSHRINK
TUBING
POWER CABLE
TUBING ON POWER CABLE
FIG. 18-1
TYPICAL POWER CABLE WITH
COPPER LUG INSTALLED
FIG. 18-2
CONNECT SHORT POS
(+) CABLE TO BATTERY
TO 150A CIRCUIT BREAKER
FIG. 18-3