1. Unpacking Instructions
THESE FAN MODELS ARE SUITABLE FOR WET LOCATIONS
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
1.2
Remove the Fan Motor Assembly from the protective
plastic bag. Place the Fan Motor Assembly onto the
upper foam pad with the Bottom of the Fan Motor
Assembly facing up.
The upper foam pad serves as a holder for the Fan
during the first stages of assembly.
Tools Needed for Assembly
One Phillips Head Screwdriver
One 1/4" Blade Screwdriver
Materials
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would be
a 3-conductor (2-wire with ground) of following size:
Your new Ceiling Fan will require a Grounded Electrical
Supply Line of 120 Volts AC, 60 Hz, 15 Amp Circuit.
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable
for Fan Support of 22.7kg. (50 lbs.) or less", and use
screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are
not acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
SUCH AS PORCHES, PATIOS, AND DECKS.
One Stepladder
One Wire Stripper

2. Electrical Requirements

(Continued)
Installed Wire Length
Up to 50 ft.
50-100 ft.
Your Emerson Ceiling Fan comes supplied with a
DC Receiver and Remote Control. This system allows
you to regulate your Ceiling Fan Speed and Accessory
LK354 Light Control.
!
Before assembling your ceiling fan, refer to section
on proper method of wiring your fan (page 13).
If you feel you do not have enough wiring knowledge
or experience, have your fan installed by a licensed
electrician.
The Outlet Box must be securely anchored and capable
of withstanding a load of at least 50 Pounds.
If your Fan is to replace an existing ceiling light fixture,
turn electricity OFF at the Main Fuse Box at this time
and remove the existing light fixture.
!
To avoid fire or shock, follow all wiring instructions
carefully.
A n y e l e c t r i c a l w o r k n o t d e s c r i b e d i n t h e s e
instructions should be done or approved by a licensed
electrician.
Please call Technical Support at 1-800-654-3545
if you have any questions about installation and
operation of this Ceiling Fan.
4
Wire Size A.W.G.
14
12
WARNING
WARNING
ETL Model No.: CF344 & CF354