Remove the mechanical opening stop and position it at the far end.
Open the gate to the max opening position, place the mechanical stop against it with the pin attachment and fi x it in place.
Connect the gearmotors to the panel as shown in the diagram.
Power
230V a.c.
50/60 Hz
Gate bracket
Pillar bracket
Extra bracket
yellow/green
blue
black
Delayed clo-
brown
sing action
yellow/green
blue
black
Delayed opening
brown
action