6.10 BLOCKING THE CONTROLS

It is possible to lock the buttons of the control panel to prevent any adjustment.
By keeping the
button pressed down for a few seconds, the control panel will be locked.
The control buttons of the boiler will be locked and no button will respond when pressed. Internally all the settings remain
the same and the boiler will function normally.
To unlock the buttons, press the same button down for a few seconds until the above displayed symbol goes off. If the boiler
is disconnected from the mains or there is a failure in the house's electricity supply, the buttons will also be unlocked.

6.11 PUMP ANTI-SEIZE FUNCTION

The advanced boiler control will automatically energize the pump for 10 seconds each month to protect it from seizing
during long periods of inactivity. The power supply must be maintained for this function to operate.

6.12 ECO SMART FUNCTION

When Eco Smart function activated, the advanced boiler control will automatically adapt the water heating process to the
individual usage conditions with the aim of reducing energy consumption. Eco Smart function will study the weekly usage of
the DHW and will use this information to get the domestic hot water ready for the periods of use, and to reduce the
temperature set-point in the non-use periods minimizing the energy losses and reducing the energy consumption. This
function can be activated with parameter P16. See "6.6 USER PARAMETERS".
i
The domestic water tank temperature during the non-use periods can be lower than the set-point DHW temperature
when Eco Smart function is activated.
39