User Parameters; Heating Modulation Feature; Legionella Protection - Gabarron MATTIRA CMX18i Instrucciones De Instalacion Y Uso

Calderas eléctricas modulantes digitales para calefacción y agua caliente sanitaria
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6.6 USER PARAMETERS.

The user can change a number of parameters to set some functions of the boiler to the needs of each customer.
To access the user parameters menu – with front display OFF, press and hold the
seconds.
To move forward or backward through the menu use the
To modify a parameter, press the
buttons. Press the
Modulation. Possible values: 1 (modulation ON), 0 (modulation OFF).
Units. It is possible to change temperature units (ºC Celsius, ºF Fahrenheit). Default value: ºC.
Legionella.
AUTO heating regulation. If a fan outdoor temperature probe is installed it is possible to activate the
auto heating regulation by shifting this parameter value to 1. Only visible when P05 is activated.
TIMAX. Maximum water flow temperature in AUTO heating mode. Only shown when P05 is activated.
TIMIN. Minimum water flow temperature in AUTO heating mode. Only shown when P05 is activated.
TEMAX. Outdoor temperature from which the water flow temperature will be TIMIN. Only shown when
P05 is activated.
TEMIN. Outdoor temperature below which the water flow temperature will be TIMAX. Only shown when
P05 is activated.
Parameters menu from P16 – P18 are only accessible for DHW & central heating boiler (P00=1).
ECO SMART.
TCON. Maintenance consumption connection time. Factory pre-set.
TSCON. Time interval between maintenance consumption. Factory pre-set

6.7 HEATING MODULATION FEATURE

The advanced control board on the boiler will automatically modulate the heating output to the demand required to save
energy.
This function works by the boiler 'learning' and anticipating the time taken to reach the temperature level demanded by the
external thermostatic control. The power output is automatically adjusted therefore reducing power consumption on
warmer days or when another heat source is present.
An external 'volt free' control must be fitted across the terminals marked 'TA' on the PCB and the 'bridge' removed for this
function to be activated.
This feature can be disabled using parameter P08. See "6.6 USER PARAMETERS".

6.8 LEGIONELLA PROTECTION

If Legionella protection is activated, once a week the DHW temperature is raised to the maximum allowed if this
temperature has not been reached in the last 7 days. By default protection against Legionella it is disabled. This function can
be activated with parameter P10. See " 6.6 USER PARAMETERS".
button and the current value will be displayed. It can be modified with the
button to validate.
1 (Legionella protection ON)
0 (Legionella protection OFF).
1 (Eco Smart function ON)
0 (Eco Smart function OFF).
and
buttons respectively.
37
and
buttons for at least 5
and

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Mattira cmx15i

Tabla de contenido