Safe Handling
Safe Handling
12
12.1
Transport
—
Climate category
—
Temperature
—
Humidity
—
Only by qualified personnel in the manufacturer's original recyclable packaging
—
Avoid shocks, especially to the shaft end
—
If the packaging is damaged, check the motor for visible damage. Inform the carrier
and, if appropriate, the manufacturer.
12.2
Packaging
—
Cardboard packing with Instapak
—
You can return the plastic portion to the supplier (see "Disposal").
12.3
Storage
—
Climate category
—
Storage temperature
—
Humidity
—
Store only in the manufacturer's original recyclable packaging
—
Max. stacking height
—
Storage time
12.4
Maintenance / Cleaning
—
Maintenance and cleaning only by qualified personnel
—
The ball bearings should be replaced after 20,000 hours of operation under rated
conditions (by the manufacturer).
—
Check the motor for bearing noise every 2500 operating hours, respectively each
year. If any noises are heard, stop the operation of the motor, the bearings must be
replaced (by the manufacturer).
—
Opening the motor invalidates the warranty.
—
If the housing is dirty, clean housing with Isopropanol or similar, do not immerse or
spray
12.5
Repair, Disposal
Repair of the motor must be done by the manufacturer. Opening the motor invalidates the
warranty. In accordance to the WEEE-2002/96/EG-Guidelines we take old devices and
accessories back for professional disposal, if the transport costs are taken over by the
sender. Send the motor to:
English - 26
05/2016
2K2 to EN61800-2, IEC 60721-3-2
-25...+60°C, max. 20K/hr change
rel. humidity 5% - 75% , no condensation
Motor type
Packing
VLM2
Cardboard
VLM3
Cardboard
KOLLMORGEN Europe GmbH
Pempelfurtstr. 1
D-40880 Ratingen
®
foam cushion.
Max. stacking height
10
6
1K3 to EN61800-2, IEC 60721-3-2
- 5...+45°C, max. variation 20K/hr.
rel. humidity 5% - 95%, no condensation
see table in chapter "Packaging"
unlimited
Kollmorgen
Servomotors VLM