QUICK START GUIDE
QUICK START GUIDE
Before turning on power to the water heater, you MUST flush all air out of
the system, then engage the AE3 safety switch. The unit will NOT operate
until the AE3 safety switch has been engaged.
1
Mount the unit to the wall (see section 9.1, "Standard non-concealed installation", pg. 9).
2
Hook up water connections (see section 8.3, "Water connections", pg. 8).
3
Hook up electrical connections, but keep circuit breaker off. (See section 9.2, "Electrical con-
nection", pg. 10)
1
4
Open and close all connected draw-off valves at least 5 times, for at least 3 minutes total,
until all air has been purged from the pipework and the water heater.
5
Ensure there are no water leaks from any plumbing connections.
6
Engage the AE3 safety switch by firmly pressing the white reset button until it clicks and
fully locks in place (the water heater is delivered with the safety switch disengaged).
7
Turn on power to the water heater at the circuit breaker in the breaker panel.
www.stiebeleltronamericas.com
2
DCE Trend|
3