M 536991040901102019
When the PCB is connected, the LED will flash green. This indicates that the PCB is properly connected. When the central ventilation system is
activated via the remote control or the cooker hood, the higher the step the system is running on, the faster the LED will flash. When the PCB
receives a signal from the remote control, the diode will flash blue.
NOTE: If the diode flashes red, there has been a connection error and live and null connections have been swapped when installing the PCB.
ADJUSTING THE VALVE
Both the basic ventilation and forced operation modes can be adjusted on the valve motor. The adjustment shall always be made in accordance
with the regulations of the manufacturer of the ventilation system and the sound pressure table for the valve in"Pressure loss and sound pres-
sure table" on page 75.
The adjustment shall be done as follows:
INSTALLATION OF THE REMOTE CONTROL
1
Use a pointed object to carefully turn the
stop blocks for basic ventilation and forced
operation of the valve motor.
NOTE: Be careful not to damage the valve
motor or stop blocks.
2
Find the correct position for the stop blocks
using the adjustment diagram for the valve.
THERMEX CENTRALVENTILATION VILLA II
3
Mount the stop blocks onto the valve motor
again.
71