Specifications
1-1 General Specifications
LCD display :
4000 counts, 3 3/4 digit LCD readout.
Measuring rate : 1.5 times / sec.
Overrange display :
"OL" is displayed for "Ω" functions,
Actual value is shown for "A" and "V"
function.
Automatic power off time :
Approximately 30 minutes after power on.
Low battery indicator :
is displayed.
Power requirement :
9V battery type 6LR61 (IEC) Alkaline.
Battery life :
ALKALINE 9V ; 200 hours typical.
1-2 Environmental Conditions
Indoor Use only.
Calibration : One year calibration cycle.
Operating temperature :
0°C ~ 30°C (≦80% RH)
30°C ~ 40°C (≦75% RH)
40°C ~ 50°C (≦45%RH)
Storage temperature :
-20 to +60°C, 0 to 80% RH (batteries not
fitted).
Overvoltage category :
IEC 61010-1 600V CAT.Ⅲ.
CAT.Ⅲ equipment is designed to protect
against the transients in the equipment in
fixed installations, such as distribution
panels, feeders and short branch circuits
and lighting systems in large buildings.
Operating altitude : 2000m (6562 ft)
Conductor Size : 35mm diameter.
Pollution degree : 2
EMC : EN 61326-1
Shock vibration :
Sinusoidal vibration per MIL-T-28800E
(5 ~ 55 Hz, 3g maximum).
Drop Protection : 4 feet drop to
hardwood on concrete floor.